GEOSPAR can size the facing walls nailed to determine the thickness of the concrete projected position and the section reinforcement layers and the position and dimensions of the support plates.
The forces are calculated by solving the plate equation by finite differences.The reinforcement sections are calculated according to BAEL 91 rules.It is possible to consider whether a vertical continuity of reinforcement.